Underground water can
carry uranium into fractures. For this reason Uranium curve can be
increased in NGT Natural Gammray Spectoroscopy log..
|
|
If the pad of density tool
contacts to fracture it reads low density. Correction curve shows high
correction.Neutron porosity increases in fractures.
|
Resistivity decreases in
fractures.Especially MSFL tools read values close to mud resistivities.
|
We can see cycle skipping
in fractured zones. This effect is anormal high (Dt)
readings.If you can compare sound
travel times to the various receiver, you can easily see the difference
between curves. Sonic tool can not see vertical fractures..
|
In fractures caliper will
read high. If mud cake formed in the borehole, fractures can not be
identified in fractures.
|